All articles
2025
2024
2023
- Fiasp will be back!
- Support Joey's marathon
- Significant LibreLink update coming to Australia
- Heading to California
- NovoPen 6 - new reusable insulin pen
- Further comparison with HCL and non-diabetic data
- Time in ... "Stricter"? Range
- Close-It clinical trial
- Anubis revisited
- Arcane Lyumjev experiments
- Medtronic's retiring the 1.8 mL Paradigm reservoirs
- Podcast interview
- NDSS pump consumables change
- Fiasp again - time to act!
- Re-usable insulin pens
- Statins, Fibrates, and Metformin
- Adjunctive therapies
- Every day is an experiment
- Polish diabetes tech fest - April 15
- An experimental OJ
- Last day for getting a Fiasp prescription
- Progressing through Hybrid and "Fully" Closed-looping
- Ranges and Timeframes
- Varying basals vs ISF, and The Break-Fast Phenomenon
- Does HbA1c have value?
- A reprieve for Fiasp
- Economics of insulin from a PBS-user perspective
- When is insulin aspart not NovoRapid?
- Fiasp PBS deletion confirmed
- Advocacy groups that don't advocate?
- Catastrophic Insulin decisions in Australia
- Clinical research news
- Basal impacts of insulin speed
2022
- Insulin timings (2022)
- "Pancreas phone" updates
- Finally! Australian Omnipod subsidy
- Media scares about Omnipods
- Maintaining Bluetooth connections with CGMs and pumps
- Securing CGM sensors: a postscript
- Simple gadgets
- "Pancreas phone" options
- A few pump infusion sets being retired
- Speaking at ACADI summit: November 14
- Moving a Dexcom G6 sensor between phones
- Art competitions and diabetes
- 40 years and ticking
- Medtronic InPen is launched in Australia
- Emergency backups: a pen that can use PumpCart insulin
- Quinquennial looping!
- Mixing CamAPS with xDrip+
- Recent changes to BG meters
- Medtronic tease the InPen
- Stories from the 2022 ADC
- 2022 Australasian Diabetes Congress
- Another closed-loop
- Securing CGM sensors
- Insulin Pump Choices update - July 2022
- NDSS CGM Subsidy (for T1) progress!
- CGM Calibration and Cats
- CGM Subsidy updates - dribs and drabs
- June CGM Subsidy update
- Recent insulin pump safety notices
- CGM Subsidy update: what DO we know?
- May 2022 data snapshot
- CGM4allT1 subsidy - a new world in 2022
- Omnipod options in Australia
- Planning for possible obsolescence
- "Have I cooked my insulin" redux
- Insulin pump infusion sets - NDSS
- The Dragon's Tail
- Revised Humalog model in a closed loop
- Fiasp "Penfill" revisited
- Dexcom G6 warmup
- Insulin Pump Choices update - April 2022
- End of Daylight Saving Time. Again.
- Feral diabetes
- We can't manage what we don't measure
- Hyperinsulinaemia
- Looping backup/restore in the field
- JDRF Type One Summit
- Fun with icons
- Mixing insulins - theory and practice
- Control-IQ in Australia
- GMI and HbA1c revisited
- One year of no-bolus looping: data analysis
- Dexcom G6 now on NDSS. Dexcom G5 being retired!
- A year of fully-closed looping
- Insulin Pump Choices - February 2022 update
- Lyumjev update
- Goodbye Semglee
2021
- Lyumjev
- Yeah, but you're low-carb
- December Australian insulin pump updates
- Filling an Omnipod
- Podding observations
- An insulin pump update waiting in the wings
- Loopable pumps - a visual comparison
- Inset II for the Combo pump
- The return to Fiasp
- Another year ticks by
- Pump environmental limits
- September Australian Insulin Pump changes
- Omnipod DASH observations
- Comparing multiple insulins
- Using a different insulin
- Another milestone - 4 years of looping
- August update to Australian Insulin Pump Choices
- Libre 2 in Australia at last
- Pumping with a secondhand pump
- Australian Insulin Pump Choices update - July 2021
- A piggy-backed trial - how good is that BG meter?
- ATTD'2021: hanging on to the fire-hose
- Anubis developments
- Control-IQ – when?
- Changes in Accu-Chek BG meter lineup
- Eversense implanted CGM
- Subtleties of insulin duration
- Australian Insulin Pump Choices - April 2021 update
- It's not always diabetes
- No-bolus for 4 months
- Dexcom robustness: unique IDs and names
- The t:slim is back
- Does insulin X work in pump Y ?
- Pump occlusion alarms
- Anubis - the G6 reborn!
- Libre 2
- Streaking
- Medicine information
- 2021 vaccines
- Pump refill kits
- New interferent for Dexcom CGMs
- A new "pancreas phone"
- Magazine publication
- Massive CGM price hike in Australia
- Living with an actual closed loop
- Finding insights from CGM data
- Please lend your voice to the call for CGM access for all
- The Aviva is dead. Long live the Aviva!
2020
- Safety Net again
- Christmas on a no-bolus loop
- CoolPod - dangerous for insulin!
- YpsoPump experiences - December 2020
- Australian Insulin Pump choices - December 2020 update
- Daylight Saving Time again!
- Another year of diabetes goes by
- Estimating HbA1c results
- A new Contour Next
- The Quantified Self: a normal day with Type 1 Diabetes
- Australian Insulin Pump choices - July 2020 update
- Hello Winter my old friend!
- Defining the edges of your range
- Medtronic finally retires the name “Paradigm”
- Detecting a failed pump site
- Why carb counting can be hard
- 10 days of Fiasp
- April NDSS changes - Medtronic drops some infusion sets
- Long-term CGM analysis
- What's "normal"?
- G6 at last?
- CGM metrics: GVI/PGS
- A complicated topic
- "Tight control" - what does it mean?
- US safety notice for Medtronic 600-series pumps
- "Non-diabetic" glucose levels
- That time the Wookiee DIDN'T become more Bionic
- End of an era - or is it?
- Is your BOB ready?
- Lantus is being replaced
- Minimizing CGM gaps
- New Year: new Safety Nets
- Looping press coverage in WA
2019
- Take nothing for granted
- GMI - is it useful?
- Fasting blood tests again
- A new low: a good one!
- Revisiting Fiasp
- Faults in some BG meters
- Australian Insulin Pump choices - November 2019 update
- Another role
- AndroidAPS 2.5
- Revisiting the topic of filling pump cannulae
- HbA1c does NOT make a good target
- 37 years of diabetes
- Another insulin - October 2019
- NDSS updates - October 2019
- Daylight Saving is coming
- DIY Looping on ABC TV
- TIR expectations
- The CGM sky is not falling. Probably.
- Legal action to stop cheaper CGM?
- Accu-Chek Solo - wearing a dummy
- Cheaper CGM!
- ADC 2019 - Day 2
- Another luer-lock infusion set option
- ADC 2019 - Day 1
- Loopaversary 2019
- A week of Australian diabetes news
- Medical ID jewellery
- BG graph scales
- Animas finally going away
- Disaster management - Internet dependencies
- Bolus speeds - how fast is your pump?
- Targets and Goals
- Hiccups with NDSS supply of pump consumables - July 2019
- Priming infusion lines
- The 4Ts: signs of Type 1 Diabetes
- A matter of perspective
- Using Fiasp in a pump
- Demise of a clinical trial
- DIY Looping on the radio
- No Penfill? Side-effects of PBS decisions
- March/April 2019 Australian looping survey
- Accessing supplies through pharmacies
- Duration of Insulin Action
- Is Fiasp safe?
- Using Fiasp in a DIY loop
- Fiasp insulin in Australia
- Another DIY diabetes tech get-together
- Filling the fridge with drugs
- Saved by the old cannula
- Looping through an Exercise Weekend
- CGM sensor locations
- Time to refill the pump reservoir
- April 2019 Australian insulin pump update
- Accu-Chek Guide Me meter
- The end of Daylight Saving Time
- Cellnovo closes
- Cellnovo's uncertain future
- March/April looping survey
- Details of Bigfoot Biomedical's pump
- Insulin - do you have a backup plan?
- Looping through another hospital visit
- Participating in clinical trials
- Living with coeliac disease
- Closed-loop pumps in Australia - March 2019
- Misunderstandings about DIY looping
- Time for another driving licence review
- Spare a Rose
- A closed loop is not every closed loop - 670G
- Life in 5-minute slices
- Tandem pumps in Australia are changing
- Orbit cannulas - one design, many brands
- Contour Next BG meters
- Another CGM!
- Summer heat!
2018
- A different office for the rest of December
- CGM calibration reminders
- December Melbourne looping workshop
- Closed-loop pump options - November 2018
- Australian Insulin Pumps - November 2018
- Segal's Law
- CGM accuracy - Calibration is King!
- Have I cooked my insulin?
- In hospital with a closed-loop pump
- Published in the Internal Medicine Journal
- JDRF Type One Summit - Melbourne
- Living with Technology - ADATS 2018
- Apidra and Tandem pumps do not mix!
- Sydney closed-loop event: Sat 20th October
- My insulin pump
- Travel planning with diabetes
- LibreLinkUp - "follower" app reaches Australia
- Australian DIY APS looping survey, September 2018
- 36 years down!
- Libre version 2
- NDSS supplies product lists updated
- Cellnovo's new handset
- Not wasting infusion set tubing
- Re-taping my CGM sensor
- Insulin pumps in Australia - August 2018
- My Apidra experience
- Filling a cannula
- When to change pump cannula and reservoir
- Contour Next One - new BG meter for Australia
- An official Position Statement on DIY diabetes technology!
- My favourite BG meters
- Libre subsidy: how is it related to BG meter choice?
- Accu-Chek Performa BG meter - a last-minute purchase
- Travelling with Type 1 - July 2018
- Software as a Medical Device: TGA and CSIRO
- Tandem cannulae and upgrades
- Catching up with July
- A busy month in Adelaide
- Travelling with diabetes technology
- How accurate is the Libre Reader?
- Why do some insulin pumps crack?
- Tandem pump info - July 2018
- Do you trust your meter?
- New insulin pumps for Australia
- What's a container of insulin called?
- When is a 670G not a 670G?
- Diabetes population: Australian snapshot
- Ypsopump launches in Australia!
- Medtrum A6 TouchCare pump
- Another "new" insulin for Australia
- Is your insulin pump waterproof? What does that actually mean?
- April 2018 Australian insulin pump update
- Managing sharps safely
- Backup insulin pens
- "Hard" or "soft" expiry dates: a Spirit Combo story
- Cleo 90 infusion set - forgotten but not gone?
- Pump cannulae and infusion sets: what are the differences?
- What's in a needle?
- April 1st - new insulin, new pump
- March thoughts on insulin pumps for Australia
- Real-world design input required!
- The times they are a-changing
- Fasting glucose tests
- Nasal blouses - autocorrect annoyances
- Basal increments in pumps
- News from Europe
- New insulin pump for Australia!
- Pump reservoirs - size comparison
- Sydney DIY APS build day, February 2018
- Melbourne DIY APS build weekend, January 2018
- Animas announces Australian pump exit
- Batteries for DANA pumps
2017
- AAA batteries for insulin pumps - updated data
- Sleep - better with a loop or not?
- "Looping and Alive" and other apparel
- AAA batteries for insulin pumps - Part 2
- Carrying CR2032 batteries
- World Diabetes Day - November 14
- Cellnovo finally arrives
- Which pump is that?
- Calibration is critical for looping
- Connected BG meters
- Not your average pump
- AAA batteries for insulin pumps
- Repeating calendar appointments
- Step up Roche!
- Animas pumps are going away!
- Changing a G5 sensor
- NDSS updates
- End of the first G5 sensor
- 35 years old
- CGM: switching between Libre and G5
- Tegaderm Film 1624W
- Waterproofing the Libre Reader
- We live in interesting times
- Managing used test strips
- Dual cannulas
- Living with a disease
- GERTY
- Failure is not an option
- JARVIS